hwmon: (lm90) Introduce capability flag to indicate broken ALERT functionality
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Signed-off-by: Jean Delvare <khali@linux-fr.org>
This commit is contained in:
parent
4667bcb8d8
commit
1179324c41
|
@ -162,6 +162,7 @@ enum chips { lm90, adm1032, lm99, lm86, max6657, max6659, adt7461, max6680,
|
||||||
#define LM90_HAVE_EMERGENCY (1 << 4) /* 3rd upper (emergency) limit */
|
#define LM90_HAVE_EMERGENCY (1 << 4) /* 3rd upper (emergency) limit */
|
||||||
#define LM90_HAVE_EMERGENCY_ALARM (1 << 5)/* emergency alarm */
|
#define LM90_HAVE_EMERGENCY_ALARM (1 << 5)/* emergency alarm */
|
||||||
#define LM90_HAVE_TEMP3 (1 << 6) /* 3rd temperature sensor */
|
#define LM90_HAVE_TEMP3 (1 << 6) /* 3rd temperature sensor */
|
||||||
|
#define LM90_HAVE_BROKEN_ALERT (1 << 7) /* Broken alert */
|
||||||
|
|
||||||
/*
|
/*
|
||||||
* Driver data (common to all clients)
|
* Driver data (common to all clients)
|
||||||
|
@ -200,11 +201,13 @@ struct lm90_params {
|
||||||
|
|
||||||
static const struct lm90_params lm90_params[] = {
|
static const struct lm90_params lm90_params[] = {
|
||||||
[adm1032] = {
|
[adm1032] = {
|
||||||
.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
|
.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
|
||||||
|
| LM90_HAVE_BROKEN_ALERT,
|
||||||
.alert_alarms = 0x7c,
|
.alert_alarms = 0x7c,
|
||||||
},
|
},
|
||||||
[adt7461] = {
|
[adt7461] = {
|
||||||
.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
|
.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
|
||||||
|
| LM90_HAVE_BROKEN_ALERT,
|
||||||
.alert_alarms = 0x7c,
|
.alert_alarms = 0x7c,
|
||||||
},
|
},
|
||||||
[lm86] = {
|
[lm86] = {
|
||||||
|
@ -1361,7 +1364,7 @@ static void lm90_alert(struct i2c_client *client, unsigned int flag)
|
||||||
/* Disable ALERT# output, because these chips don't implement
|
/* Disable ALERT# output, because these chips don't implement
|
||||||
SMBus alert correctly; they should only hold the alert line
|
SMBus alert correctly; they should only hold the alert line
|
||||||
low briefly. */
|
low briefly. */
|
||||||
if ((data->kind == adm1032 || data->kind == adt7461)
|
if ((data->flags & LM90_HAVE_BROKEN_ALERT)
|
||||||
&& (alarms & data->alert_alarms)) {
|
&& (alarms & data->alert_alarms)) {
|
||||||
dev_dbg(&client->dev, "Disabling ALERT#\n");
|
dev_dbg(&client->dev, "Disabling ALERT#\n");
|
||||||
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
|
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
|
||||||
|
|
Loading…