wl1251: timeout one too soon in wl1251_boot_run_firmware()
`loop' reaches INIT_LOOP + 1 after the loop. so if ACX_INTR_INIT_COMPLETE occurs in the last iteration the write occurs but also the error out as if a timeout occurred. This is probably very unlikely to ever occur. Signed-off-by: Roel Kluin <roel.kluin@gmail.com> Acked-by: Kalle Valo <kalle.valo@nokia.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
24feda0084
commit
e8a4a6df73
|
@ -256,7 +256,7 @@ int wl1251_boot_run_firmware(struct wl1251 *wl)
|
|||
}
|
||||
}
|
||||
|
||||
if (loop >= INIT_LOOP) {
|
||||
if (loop > INIT_LOOP) {
|
||||
wl1251_error("timeout waiting for the hardware to "
|
||||
"complete initialization");
|
||||
return -EIO;
|
||||
|
|