wm97xx_battery: Clean up some warnings
Staticise work_lock (nothing outside the driver has any reason to see it) and specify dev when requesting the charger IRQ (since that's what we pass in when we free it). Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Acked-by: Marek Vasut <marek.vasut@gmail.com> Signed-off-by: Anton Vorontsov <avorontsov@ru.mvista.com>
This commit is contained in:
parent
12b336a8b4
commit
f8d94eb77e
|
@ -26,7 +26,7 @@
|
|||
|
||||
static DEFINE_MUTEX(bat_lock);
|
||||
static struct work_struct bat_work;
|
||||
struct mutex work_lock;
|
||||
static struct mutex work_lock;
|
||||
static int bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
|
||||
static struct wm97xx_batt_info *gpdata;
|
||||
static enum power_supply_property *prop;
|
||||
|
@ -203,7 +203,7 @@ static int __devinit wm97xx_bat_probe(struct platform_device *dev)
|
|||
goto err2;
|
||||
ret = request_irq(gpio_to_irq(pdata->charge_gpio),
|
||||
wm97xx_chrg_irq, IRQF_DISABLED,
|
||||
"AC Detect", 0);
|
||||
"AC Detect", dev);
|
||||
if (ret)
|
||||
goto err2;
|
||||
props++; /* POWER_SUPPLY_PROP_STATUS */
|
||||
|
|