linux-stable-rt/drivers/net/netxen
Mithlesh Thukral c27e672172 NetXen: Fix link status messages
NetXen: Fix incorrect link status even with switch turned OFF.
NetXen driver failed to accurately indicate when a link is up or down.
This was encountered during failover testing, when the first port
indicated that the link was up even when the 10G switch it was assigned
to in the Bladecenter was turned off completely.

Signed-off by: Wen Xiong <wenxiong@us.ibm.com>
Signed-off by: Mithlesh Thukral <mithlesh@netxen.com>

Signed-off-by: Jeff Garzik <jeff@garzik.org>
2007-06-12 18:58:58 -04:00
..
Makefile
netxen_nic.h NetXen: Fix link status messages 2007-06-12 18:58:58 -04:00
netxen_nic_ethtool.c NetXen: Fix compile failure seen on PPC architecture 2007-06-09 18:25:35 -04:00
netxen_nic_hdr.h
netxen_nic_hw.c NetXen: Fix compile failure seen on PPC architecture 2007-06-09 18:25:35 -04:00
netxen_nic_hw.h
netxen_nic_init.c NetXen: Fix link status messages 2007-06-12 18:58:58 -04:00
netxen_nic_isr.c NetXen: Fix link status messages 2007-06-12 18:58:58 -04:00
netxen_nic_main.c NetXen: Fix ping issue after reboot on Blades with 3.4.19 firmware 2007-06-09 18:25:34 -04:00
netxen_nic_niu.c NetXen: Fix ping issue after reboot on Blades with 3.4.19 firmware 2007-06-09 18:25:34 -04:00
netxen_nic_phan_reg.h