e4fe19819e
Patch from Lennert Buytenhek The IXP2000 has four timers, but if we're on an A-step IXP2800, timer 2 and 3 don't work. We need two timers for timekeeping (one for the timer interrupt and one for tracking missed jiffies), so on early IXP2800s we have no other choice but to use timer 1 and 4 for that, but on all other IXP2000s we'd rather leave timer 4 free since that's the only timer we can use for the watchdog. So, on buggy IXP2000s (i.e. the A-step IXP2800) we use timer 4 for tracking missed jiffies, and on all all non-buggy IXP2000s (i.e. everything but the A-step IXP2800) we use timer 2. On a pre-production IXP2800, this patch should print these messages on boot: Enabling IXP2800 erratum #25 workaround Unable to use IXP2000 watchdog due to IXP2800 erratum #25 On any non-buggy IXP2800 (as well as on IXP2400s) you shouldn't see anything at all, and the watchdog should be usable again. Signed-off-by: Lennert Buytenhek Signed-off-by: Deepak Saxena Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk> |
||
---|---|---|
.. | ||
alpha | ||
arm | ||
arm26 | ||
cris | ||
frv | ||
h8300 | ||
i386 | ||
ia64 | ||
m32r | ||
m68k | ||
m68knommu | ||
mips | ||
parisc | ||
ppc | ||
ppc64 | ||
s390 | ||
sh | ||
sh64 | ||
sparc | ||
sparc64 | ||
um | ||
v850 | ||
x86_64 |