343 lines
8.2 KiB
C
343 lines
8.2 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* intel_rapl_tpmi: Intel RAPL driver via TPMI interface
|
|
*
|
|
* Copyright (c) 2023, Intel Corporation.
|
|
* All Rights Reserved.
|
|
*
|
|
*/
|
|
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
|
|
|
#include <linux/auxiliary_bus.h>
|
|
#include <linux/io.h>
|
|
#include <linux/intel_tpmi.h>
|
|
#include <linux/intel_rapl.h>
|
|
#include <linux/module.h>
|
|
#include <linux/slab.h>
|
|
|
|
#define TPMI_RAPL_VERSION 1
|
|
|
|
/* 1 header + 10 registers + 5 reserved. 8 bytes for each. */
|
|
#define TPMI_RAPL_DOMAIN_SIZE 128
|
|
|
|
enum tpmi_rapl_domain_type {
|
|
TPMI_RAPL_DOMAIN_INVALID,
|
|
TPMI_RAPL_DOMAIN_SYSTEM,
|
|
TPMI_RAPL_DOMAIN_PACKAGE,
|
|
TPMI_RAPL_DOMAIN_RESERVED,
|
|
TPMI_RAPL_DOMAIN_MEMORY,
|
|
TPMI_RAPL_DOMAIN_MAX,
|
|
};
|
|
|
|
enum tpmi_rapl_register {
|
|
TPMI_RAPL_REG_HEADER,
|
|
TPMI_RAPL_REG_UNIT,
|
|
TPMI_RAPL_REG_PL1,
|
|
TPMI_RAPL_REG_PL2,
|
|
TPMI_RAPL_REG_PL3,
|
|
TPMI_RAPL_REG_PL4,
|
|
TPMI_RAPL_REG_RESERVED,
|
|
TPMI_RAPL_REG_ENERGY_STATUS,
|
|
TPMI_RAPL_REG_PERF_STATUS,
|
|
TPMI_RAPL_REG_POWER_INFO,
|
|
TPMI_RAPL_REG_DOMAIN_INFO,
|
|
TPMI_RAPL_REG_INTERRUPT,
|
|
TPMI_RAPL_REG_MAX = 15,
|
|
};
|
|
|
|
struct tpmi_rapl_package {
|
|
struct rapl_if_priv priv;
|
|
struct intel_tpmi_plat_info *tpmi_info;
|
|
struct rapl_package *rp;
|
|
void __iomem *base;
|
|
struct list_head node;
|
|
};
|
|
|
|
static LIST_HEAD(tpmi_rapl_packages);
|
|
static DEFINE_MUTEX(tpmi_rapl_lock);
|
|
|
|
static struct powercap_control_type *tpmi_control_type;
|
|
|
|
static int tpmi_rapl_read_raw(int id, struct reg_action *ra)
|
|
{
|
|
if (!ra->reg.mmio)
|
|
return -EINVAL;
|
|
|
|
ra->value = readq(ra->reg.mmio);
|
|
|
|
ra->value &= ra->mask;
|
|
return 0;
|
|
}
|
|
|
|
static int tpmi_rapl_write_raw(int id, struct reg_action *ra)
|
|
{
|
|
u64 val;
|
|
|
|
if (!ra->reg.mmio)
|
|
return -EINVAL;
|
|
|
|
val = readq(ra->reg.mmio);
|
|
|
|
val &= ~ra->mask;
|
|
val |= ra->value;
|
|
|
|
writeq(val, ra->reg.mmio);
|
|
return 0;
|
|
}
|
|
|
|
static struct tpmi_rapl_package *trp_alloc(int pkg_id)
|
|
{
|
|
struct tpmi_rapl_package *trp;
|
|
int ret;
|
|
|
|
mutex_lock(&tpmi_rapl_lock);
|
|
|
|
if (list_empty(&tpmi_rapl_packages)) {
|
|
tpmi_control_type = powercap_register_control_type(NULL, "intel-rapl", NULL);
|
|
if (IS_ERR(tpmi_control_type)) {
|
|
ret = PTR_ERR(tpmi_control_type);
|
|
goto err_unlock;
|
|
}
|
|
}
|
|
|
|
trp = kzalloc(sizeof(*trp), GFP_KERNEL);
|
|
if (!trp) {
|
|
ret = -ENOMEM;
|
|
goto err_del_powercap;
|
|
}
|
|
|
|
list_add(&trp->node, &tpmi_rapl_packages);
|
|
|
|
mutex_unlock(&tpmi_rapl_lock);
|
|
return trp;
|
|
|
|
err_del_powercap:
|
|
if (list_empty(&tpmi_rapl_packages))
|
|
powercap_unregister_control_type(tpmi_control_type);
|
|
err_unlock:
|
|
mutex_unlock(&tpmi_rapl_lock);
|
|
return ERR_PTR(ret);
|
|
}
|
|
|
|
static void trp_release(struct tpmi_rapl_package *trp)
|
|
{
|
|
mutex_lock(&tpmi_rapl_lock);
|
|
list_del(&trp->node);
|
|
|
|
if (list_empty(&tpmi_rapl_packages))
|
|
powercap_unregister_control_type(tpmi_control_type);
|
|
|
|
kfree(trp);
|
|
mutex_unlock(&tpmi_rapl_lock);
|
|
}
|
|
|
|
/*
|
|
* Bit 0 of TPMI_RAPL_REG_DOMAIN_INFO indicates if the current package is a domain
|
|
* root or not. Only domain root packages can enumerate System (Psys) Domain.
|
|
*/
|
|
#define TPMI_RAPL_DOMAIN_ROOT BIT(0)
|
|
|
|
static int parse_one_domain(struct tpmi_rapl_package *trp, u32 offset)
|
|
{
|
|
u8 tpmi_domain_version;
|
|
enum rapl_domain_type domain_type;
|
|
enum tpmi_rapl_domain_type tpmi_domain_type;
|
|
enum tpmi_rapl_register reg_index;
|
|
enum rapl_domain_reg_id reg_id;
|
|
int tpmi_domain_size, tpmi_domain_flags;
|
|
u64 tpmi_domain_header = readq(trp->base + offset);
|
|
u64 tpmi_domain_info;
|
|
|
|
/* Domain Parent bits are ignored for now */
|
|
tpmi_domain_version = tpmi_domain_header & 0xff;
|
|
tpmi_domain_type = tpmi_domain_header >> 8 & 0xff;
|
|
tpmi_domain_size = tpmi_domain_header >> 16 & 0xff;
|
|
tpmi_domain_flags = tpmi_domain_header >> 32 & 0xffff;
|
|
|
|
if (tpmi_domain_version != TPMI_RAPL_VERSION) {
|
|
pr_warn(FW_BUG "Unsupported version:%d\n", tpmi_domain_version);
|
|
return -ENODEV;
|
|
}
|
|
|
|
/* Domain size: in unit of 128 Bytes */
|
|
if (tpmi_domain_size != 1) {
|
|
pr_warn(FW_BUG "Invalid Domain size %d\n", tpmi_domain_size);
|
|
return -EINVAL;
|
|
}
|
|
|
|
/* Unit register and Energy Status register are mandatory for each domain */
|
|
if (!(tpmi_domain_flags & BIT(TPMI_RAPL_REG_UNIT)) ||
|
|
!(tpmi_domain_flags & BIT(TPMI_RAPL_REG_ENERGY_STATUS))) {
|
|
pr_warn(FW_BUG "Invalid Domain flag 0x%x\n", tpmi_domain_flags);
|
|
return -EINVAL;
|
|
}
|
|
|
|
switch (tpmi_domain_type) {
|
|
case TPMI_RAPL_DOMAIN_PACKAGE:
|
|
domain_type = RAPL_DOMAIN_PACKAGE;
|
|
break;
|
|
case TPMI_RAPL_DOMAIN_SYSTEM:
|
|
if (!(tpmi_domain_flags & BIT(TPMI_RAPL_REG_DOMAIN_INFO))) {
|
|
pr_warn(FW_BUG "System domain must support Domain Info register\n");
|
|
return -ENODEV;
|
|
}
|
|
tpmi_domain_info = readq(trp->base + offset + TPMI_RAPL_REG_DOMAIN_INFO);
|
|
if (!(tpmi_domain_info & TPMI_RAPL_DOMAIN_ROOT))
|
|
return 0;
|
|
domain_type = RAPL_DOMAIN_PLATFORM;
|
|
break;
|
|
case TPMI_RAPL_DOMAIN_MEMORY:
|
|
domain_type = RAPL_DOMAIN_DRAM;
|
|
break;
|
|
default:
|
|
pr_warn(FW_BUG "Unsupported Domain type %d\n", tpmi_domain_type);
|
|
return -EINVAL;
|
|
}
|
|
|
|
if (trp->priv.regs[domain_type][RAPL_DOMAIN_REG_UNIT].mmio) {
|
|
pr_warn(FW_BUG "Duplicate Domain type %d\n", tpmi_domain_type);
|
|
return -EINVAL;
|
|
}
|
|
|
|
reg_index = TPMI_RAPL_REG_HEADER;
|
|
while (++reg_index != TPMI_RAPL_REG_MAX) {
|
|
if (!(tpmi_domain_flags & BIT(reg_index)))
|
|
continue;
|
|
|
|
switch (reg_index) {
|
|
case TPMI_RAPL_REG_UNIT:
|
|
reg_id = RAPL_DOMAIN_REG_UNIT;
|
|
break;
|
|
case TPMI_RAPL_REG_PL1:
|
|
reg_id = RAPL_DOMAIN_REG_LIMIT;
|
|
trp->priv.limits[domain_type] |= BIT(POWER_LIMIT1);
|
|
break;
|
|
case TPMI_RAPL_REG_PL2:
|
|
reg_id = RAPL_DOMAIN_REG_PL2;
|
|
trp->priv.limits[domain_type] |= BIT(POWER_LIMIT2);
|
|
break;
|
|
case TPMI_RAPL_REG_PL4:
|
|
reg_id = RAPL_DOMAIN_REG_PL4;
|
|
trp->priv.limits[domain_type] |= BIT(POWER_LIMIT4);
|
|
break;
|
|
case TPMI_RAPL_REG_ENERGY_STATUS:
|
|
reg_id = RAPL_DOMAIN_REG_STATUS;
|
|
break;
|
|
case TPMI_RAPL_REG_PERF_STATUS:
|
|
reg_id = RAPL_DOMAIN_REG_PERF;
|
|
break;
|
|
case TPMI_RAPL_REG_POWER_INFO:
|
|
reg_id = RAPL_DOMAIN_REG_INFO;
|
|
break;
|
|
default:
|
|
continue;
|
|
}
|
|
trp->priv.regs[domain_type][reg_id].mmio = trp->base + offset + reg_index * 8;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int intel_rapl_tpmi_probe(struct auxiliary_device *auxdev,
|
|
const struct auxiliary_device_id *id)
|
|
{
|
|
struct tpmi_rapl_package *trp;
|
|
struct intel_tpmi_plat_info *info;
|
|
struct resource *res;
|
|
u32 offset;
|
|
int ret;
|
|
|
|
info = tpmi_get_platform_data(auxdev);
|
|
if (!info)
|
|
return -ENODEV;
|
|
|
|
trp = trp_alloc(info->package_id);
|
|
if (IS_ERR(trp))
|
|
return PTR_ERR(trp);
|
|
|
|
if (tpmi_get_resource_count(auxdev) > 1) {
|
|
dev_err(&auxdev->dev, "does not support multiple resources\n");
|
|
ret = -EINVAL;
|
|
goto err;
|
|
}
|
|
|
|
res = tpmi_get_resource_at_index(auxdev, 0);
|
|
if (!res) {
|
|
dev_err(&auxdev->dev, "can't fetch device resource info\n");
|
|
ret = -EIO;
|
|
goto err;
|
|
}
|
|
|
|
trp->base = devm_ioremap_resource(&auxdev->dev, res);
|
|
if (IS_ERR(trp->base)) {
|
|
ret = PTR_ERR(trp->base);
|
|
goto err;
|
|
}
|
|
|
|
for (offset = 0; offset < resource_size(res); offset += TPMI_RAPL_DOMAIN_SIZE) {
|
|
ret = parse_one_domain(trp, offset);
|
|
if (ret)
|
|
goto err;
|
|
}
|
|
|
|
trp->tpmi_info = info;
|
|
trp->priv.type = RAPL_IF_TPMI;
|
|
trp->priv.read_raw = tpmi_rapl_read_raw;
|
|
trp->priv.write_raw = tpmi_rapl_write_raw;
|
|
trp->priv.control_type = tpmi_control_type;
|
|
|
|
/* RAPL TPMI I/F is per physical package */
|
|
trp->rp = rapl_find_package_domain(info->package_id, &trp->priv, false);
|
|
if (trp->rp) {
|
|
dev_err(&auxdev->dev, "Domain for Package%d already exists\n", info->package_id);
|
|
ret = -EEXIST;
|
|
goto err;
|
|
}
|
|
|
|
trp->rp = rapl_add_package(info->package_id, &trp->priv, false);
|
|
if (IS_ERR(trp->rp)) {
|
|
dev_err(&auxdev->dev, "Failed to add RAPL Domain for Package%d, %ld\n",
|
|
info->package_id, PTR_ERR(trp->rp));
|
|
ret = PTR_ERR(trp->rp);
|
|
goto err;
|
|
}
|
|
|
|
rapl_package_add_pmu(trp->rp);
|
|
|
|
auxiliary_set_drvdata(auxdev, trp);
|
|
|
|
return 0;
|
|
err:
|
|
trp_release(trp);
|
|
return ret;
|
|
}
|
|
|
|
static void intel_rapl_tpmi_remove(struct auxiliary_device *auxdev)
|
|
{
|
|
struct tpmi_rapl_package *trp = auxiliary_get_drvdata(auxdev);
|
|
|
|
rapl_package_remove_pmu(trp->rp);
|
|
rapl_remove_package(trp->rp);
|
|
trp_release(trp);
|
|
}
|
|
|
|
static const struct auxiliary_device_id intel_rapl_tpmi_ids[] = {
|
|
{.name = "intel_vsec.tpmi-rapl" },
|
|
{ }
|
|
};
|
|
|
|
MODULE_DEVICE_TABLE(auxiliary, intel_rapl_tpmi_ids);
|
|
|
|
static struct auxiliary_driver intel_rapl_tpmi_driver = {
|
|
.probe = intel_rapl_tpmi_probe,
|
|
.remove = intel_rapl_tpmi_remove,
|
|
.id_table = intel_rapl_tpmi_ids,
|
|
};
|
|
|
|
module_auxiliary_driver(intel_rapl_tpmi_driver)
|
|
|
|
MODULE_IMPORT_NS(INTEL_TPMI);
|
|
|
|
MODULE_DESCRIPTION("Intel RAPL TPMI Driver");
|
|
MODULE_LICENSE("GPL");
|