Trusted Firmware-A (TF-A) for rk3399 implements a SiP call to get the
on-die termination (ODT) and auto power down parameters from kernel,
this patch adds the functionality to do this. Also, if DDR clock
frequency is lower than the on-die termination (ODT) disable frequency
this driver should disable the DDR ODT.
Signed-off-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Gaël PORTAY <gael.portay@collabora.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>